Description
The Grating Spectrophotometer YR05495 by Kalstein is ingeniously designed to provide unrivaled precision in color analysis across a multitude of industrial sectors such as electronics, cosmetics, textiles, plastics, automotive, and food production. This advanced spectrophotometer features three measurement apertures (φ8 mm, φ4 mm, 1×3 mm) and utilizes cutting-edge 1000-line precision grating technology. With a silicon photodiode array sensor and a comprehensive full-spectrum LED light source, it ensures consistent and accurate color evaluation in the visible wavelength range (400-700 nm). Its dual optical structure, offering both SCI and SCE measurements, makes the YR05495 an unparalleled asset for laboratories and production management invested in stringent quality control.
Market Price
The Grating Spectrophotometer YR05495 stands out in the market with a competitively positioned price that varies depending on configurations and optional accessories. This pricing strategy presents a compelling value proposition for businesses eager to enhance the precision and efficiency of their color management systems. To explore personalized pricing options or generate an instant quote seamlessly via Kalstein Plus, we invite you to take the next step in your purchasing journey.
Frequently Asked Questions
- What industries can benefit from the YR05495?
This spectrophotometer is perfect for color management in industries like plastics, textiles, ceramics, and printing, especially when dealing with fluorescent samples. - Is the YR05495 compatible with PC software integration?
Certainly, it integrates effortlessly with PC color management software, enabling comprehensive analysis and management of color quality data. - What is the sample storage capacity?
The device efficiently accommodates up to 1,000 standards and 20,000 samples, facilitating orderly and precise data management.
Advantages and Disadvantages
The primary strengths of the YR05495 include its exceptional precision, boasting a standard deviation of ΔE*ab of 0.03, user-friendly ergonomic design, and capability to handle various color spaces and light sources. Its USB connectivity ensures quick data transfers. However, its application is limited to the visible wavelength range (400-700 nm), which might restrict use cases demanding broader spectra.
Field Applications
This spectrophotometer excels in quality control applications that require high color accuracy, notably within the plastics, textiles, and coating sectors. It offers detailed color analysis through its multiple measurement apertures and SCI/SCE modes, ensuring consistent product quality and reducing variation across final outputs. Additionally, it plays a crucial role in analyzing traffic signal colors and reflective films, proving its worth for both lab-centric and production line operations.
Recommendations
For optimal performance, routine calibration and maintenance in a clean environment are recommended for the YR05495. Its rechargeable lithium-ion battery supports continuous operation, with up to 6,000 measurements possible within an 8-hour duration. Discover how the YR05495 Grating Spectrophotometer can elevate your industry’s color control precision and efficiency by requesting a quote or generating one instantly through Kalstein Plus.
Features
- Three measurement apertures for varying sample sizes
- Advanced grating technology and silicon photodiode array sensor
- Dual optical structure supporting SCI and SCE measurements
- Compatibility with PC software for enhanced data management
- High capacity for storing standards and samples
Technical Specifications
Models | YR05495 |
Optical Geometry | Reflect: di:8°, de:8°(diffuse illumination, 8-degree viewing angle) |
SCI (mirror component included)/SCE; UV light source excluded | |
Complies with CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7 | |
Characteristic | Custom aperture for accurate color measurement and quality control in plastics, electronics, paint, ink, textiles, garment printing and dyeing, printing, ceramics, and measuring fluorescent samples. |
Integrating Sphere Size | Φ40mm |
Light Source | Combined full spectrum LED light source, UV light source |
Spectrophotometric Mode | Flat grid |
Sensor | Silicon photodiode array (dual row 40 groups) |
Wave Range | 400~700nm |
Wavelength Range | 10nm |
Semi-bandwidth | 10nm |
Medium Reflectance Range | 0-200% |
Measurement Aperture | A customized aperture: MAV:Φ8mm/Φ10mm; SAV:Φ4mm/Φ5mm |
Specular Component | SCI & SCE |
Color Space | CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, βxy, Munsell (C/2) |
Color Difference Formula | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00 |
Other Color Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), |
YI (ASTM D1925, ASTM 313), | |
Stain fastness, color fastness, color intensity, opacity, | |
8th Brightness, | |
Observer Angle | 2°/10° |
Illuminator | D65, A, C, D50, F2(CWF), F7(DLF), F10(TPL5), F11(TL84), F12(TL83/U30) |
Data Displayed | Spectrogram/Values, Sample Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Compensation |
Measuring Time | About 1.5s (measure SCI and SCE about 3.2s) |
Repeatability | Spectral Reflectance: MAV/SCI, Standard Deviation within 0.1% (400nm to 700nm: within 0.2%) |
Chromaticity Value: MAV/SCI, within ΔE*ab 0.04 (when a white calibration plate is measured 30 times at 5-second intervals after white calibration) | |
Error Between Instruments | AVM/SCI, Within ΔE*ab 0.2 |
(Average for 12 BCRA Series II color tiles) | |
Measurement Mode | Single measurement, average measurement (2-99 times) |
Location Method | Camera location, stabilizer cross position |
Dimension | L*W*H=129X76X217mm |
Weight | About 600g |
Power | Li-ion battery, 3.7 V, 5,000 mAh, 6,000 measurements in 8 hours |
Illuminant Lifespan | 5 years, more than 3 million times detected |
Data Displayed | 3.5-inch TFT color LCD, capacitive touch screen |
Data Port | USB, |
Data Storage | 1,000 standard pieces, 20,000 sample pieces |
Language | Simplified Chinese, English, Traditional Chinese |
Operating Environment | 0~40℃, 0~85%RH (no condensation), Altitude < 2000m |
Storage Environment | -20~50℃, 0~85%RH (no condensation) |
Standard Accessory | Power adapter, user guide, PC software (download from office website), USB cable, black and white calibration well, protective cover, wrist strap, one aperture (8mm or 4mm) |
Optional Accessory | Micro printer, dustproof box |
Notes | Specifications are subject to change without notice. |