Description
The Electrolyte Analyzer YR06396 // YR06406 is a state-of-the-art medical instrument meticulously engineered for precise and rapid measurement of electrolytes in a wide range of biological samples such as serum, plasma, whole blood, and diluted urine. Utilizing the ion-selective electrode (ISE) analysis method, this cutting-edge analyzer delivers results in less than 30 seconds per sample. Enhanced with automatic software, it guarantees stable performance by continuously monitoring and adjusting electric potentials. Its innovative bubble detection and filtration system prevents blockages, ensuring the utmost accuracy in all measurements.
Market Price
Reflecting its advanced technological capabilities, the Electrolyte Analyzer YR06396 // YR06406 is competitively priced. Although specific pricing details can vary based on providers and additional specifications, you can discover tailored financing solutions through our Kalstein Plus platform. This ensures flexibility and efficiency in your purchasing process, offering personalized quotes that suit your specific needs.
Frequently Asked Questions
What types of samples can the YR06396 // YR06406 analyze? This analyzer can handle serum, plasma, whole blood, and diluted urine.
What is the measurement speed of the YR06396 // YR06406? It provides a rapid measurement speed of less than 30 seconds per sample.
How many test results can the analyzer store? The device can store up to 10,000 test results for easy access and reporting.
Advantages and Disadvantages
Advantages:
- High Precision: Effective bubble detection and filtration ensure accurate results.
- Speed: Delivers fast results in under 30 seconds per sample.
- Large Storage: Stores a vast amount of data with up to 10,000 results.
- Cost Efficiency: Features like power failure protection and low reagent consumption enhance sustainability and economy.
Disadvantages:
- Initial Investment: Initial costs may be high for smaller labs or facilities.
- Reagent Dependency: Requires specific reagents to perform optimally, necessitating ongoing supply.
Product Usage in the Field
Widely employed in hospitals and clinical laboratories, the Electrolyte Analyzer YR06396 // YR06406 is ideal for swift and reliable electrolyte readings within busy medical environments. Its rapid measurement capabilities and automatic liquid level detection make it indispensable for high-demand scenarios. Healthcare professionals benefit from its real-time diagnostics and user-friendly interface, which guarantee consistent and dependable performance.
Recommendations
To ensure optimal functioning of the Electrolyte Analyzer YR06396 // YR06406, adhere to regular maintenance as per the manufacturer’s guidelines. It is crucial to use the recommended reagents, maintain the device within the prescribed environmental conditions, and provide adequate training for staff. These steps help leverage the device’s capabilities fully, enhancing the quality and efficiency of laboratory operations. For customized pricing and detailed product insights, visit our Kalstein Plus platform to unlock competitive funding options tailored to your lab’s needs.
Characteristics
- Sample Types: Serum, plasma, whole blood, and diluted urine
- Analysis Method: Ion selective electrode (ISE)
- Measuring Speed: Less than 30 seconds per sample
- Data Storage: Up to 10,000 results
- Printing Capability: Internal thermal printer
- Interface: RS232 port
- Operating Temperature: 10-30°C
Technical Specifications
Model | YR06396 | YR06397 | YR06398 | YR06399 | YR06400 |
Sample | serum, plasma, whole blood and dilute urine | ||||
Analysis Method | ion selective electrode(ISE) | ||||
Measuring time | ≤30s | ||||
Sample position | 39 positions (including 5 emergency and 4 functional positions) | ||||
Storage | up to 10000 test results | ||||
Printer | Internal thermal printer | ||||
Interface | RS232 port | ||||
Temperature | 10-30°C | ||||
Relative Humidity | 80% | ||||
Atmospheric pressure | 86~106 kPa | ||||
Power supply | AC220V±22V, 50Hz±1Hz | ||||
Power | <120W | ||||
Test Parameters | K Na Cl | K Na CI TCO, AG | K Na Cl iCa nCa TCa pH | K Na Cl iCa nCa TCa pH TCO₂ AG | K Na Cl Li |
Model | YR064001 | YR06402 | YR06403 | YR06404 | YR06405 | YR06406 |
Sample | serum, plasma, whole blood and dilute urine | |||||
Analysis Method | ion selective electrode(ISE) | |||||
Measuring time | ≤30s | |||||
Sample position | 39 positions (including 5 emergency and 4 functional positions) | |||||
Storage | up to 10000 test results | |||||
Printer | Internal thermal printer | |||||
Interface | RS232 port | |||||
Temperature | 10-30°C | |||||
Relative Humidity | 80% | |||||
Atmospheric pressure | 86~106 kPa | |||||
Power supply | AC220V±22V, 50Hz±1Hz | |||||
Power | <120W | |||||
Test Parameters | K Na Cl iCa nCa TCa pH Li | K Na Cl iCa nCa TCa pH Li TCO₂ AG | K Na Cl iCa nCa TCa pH Mg | K Na Cl iCa nCa TCa pH Mg TCO₂ AG | K Na Cl iCa nCa TCa pH Mg Li TCO₂ AG | K Na Cl iCa nCa TCa pH Mg Li |