Description
The Benchtop Spectrophotometer YR05478 is an exceptional high-precision instrument designed for assessing color difference and indices within various color spaces, suitable for both reflective and transparent samples. Its advanced features include automatic aperture identification and selection from three sizes: Φ25.4 mm, 8 mm, and 4 mm, which support a diverse range of samples. The dual-array 256-element CMOS sensor and the long-life xenon lamp ensure exceptional stability and measurement consistency. Additionally, a 7-inch TFT touch screen display and an impressive storage capacity for up to 20,000 records make this spectrophotometer widely applicable across industries such as paint, ink, textile, and plastics.
Market Price
The YR05478 spectrophotometer offers precision and reliability, making it a valuable investment for businesses prioritizing quality control and color consistency. Though positioned at the higher end of the market price spectrum, its extensive features provide a competitive advantage. To adapt the price to specific requirements and benefit from this advanced technology, you can access a custom quote easily and with no obligation through the Kalstein Plus platform. Act now to discover the best solution for your industry’s needs.
Frequently Asked Questions
- Is the YR05478 suitable for fluorescent samples?
Yes, it can accurately measure fluorescent samples, enhancing its versatility for different industrial applications. - What is the data storage capacity?
The YR05478 model can store up to 20,000 records, thus maintaining comprehensive measurement history. - Does the equipment measure gloss?
Yes, it also measures gloss at 8°, in addition to indices like opacity and haze, essential for quality control.
Advantages and Disadvantages
Among its advantages, the YR05478 features a robust temperature compensation system ensuring accuracy in various environments and offers a broad spectrum of color and light settings for different testing conditions. A drawback might be its requirement for regular maintenance and calibration to sustain accuracy, especially under high usage.
Field Use
Ideal for laboratories and production lines in industries such as textiles, plastics, printing, and cosmetics, the YR05478 spectrophotometer is designed to maintain precision and stability in color measurement and transfer. Its adaptability to different working conditions optimizes the quality assurance process and ensures reliability in measurements.
Recommendations
For optimal performance, periodic calibrations and operation in a controlled environment are advised. Utilizing the device’s automatic aperture selection according to the sample type significantly enhances measurement accuracy. Get your personalized quote now with Kalstein Plus to explore how the YR05478 can transform your quality control and color transfer protocols.
Technical Specifications
Model | YR05478 |
Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ;SCI (specular component included)/SCE (specular component excluded) ;Include UV / excluded UV light source Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing)SCI (specular component included)/SCE (specular component excluded) Haze(ASTM D1003), Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 |
Application | It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control. |
Integrating Sphere Size | Φ154mm |
Light Source | 360 nm to 780 nm, Combined LED Light (5 million life span) |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360-780nm |
Wavelength Interval | 10nm |
Semiband Width | 10nm |
Measured Reflectance Range | 0-200% |
Measuring Aperture | Reflective : Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; |
Transmissive : Φ30mm/Φ25mm; | |
Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position | |
Specular Component | Reflectance: SCI&SCE / Transmittance: SCI&SCE |
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) |
Other Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), |
YI (ASTM D1925, ASTM 313), | |
MI (Metamerism Index), | |
Staining Fastness, Color Fastness, Color Strength, Opacity, | |
8° Glossiness,Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003) | |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.06% (400 nm to 700 nm: within 0.05%) |
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.06% (400 nm to 700 nm: within 0.06%) | |
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.15 (Average for 12 BCRA Series II color tiles) |
Dimension | L*W*H=370x300x200mm |
Weight | Approx. 9.6kg |
Power | AC 24V, 3A Power adapter power supply |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Display | 7-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB & Print serial port |
Data Storage | Standard 1000 Pcs, Sample 20000 Pcs |
Language | Simplified Chinese, Traditional Chinese, English, |
Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
Storage Environment | -20~50℃, 0~85%RH (no condensing) |
Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber |
Optional Accessory | Micro-printer, Transmissive Test Component, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components |
Notes: The specifications are subject to change without notice. YS6003 quality management software can only be used for data management |