Description
The Grating Spectrophotometer YR05493 is an advanced tool offering precise color analysis for industries including electronics, plastics, textiles, automotive, cosmetics, and food. With three adaptable measurement apertures (φ8 mm, φ4 mm, 1×3 mm), this spectrophotometer caters to a variety of sample sizes. Featuring state-of-the-art 1000-line grating technology and a dual silicon photodiode array sensor, the YR05493 provides stable, accurate color measurements within a visible spectrum range of 400 to 700 nm. Its ergonomic design and dual d/8 optical structure support both SCI and SCE measurements, adhering to international standards such as CIE No.15 and ASTM E1164, making it indispensable for quality control in both laboratory and production settings.
Market Price
The investing in the YR05493 is a strategic move for companies aiming to boost precision and efficiency in color quality control processes. The market offers a range of configurations and accessories, which influence the overall pricing. Elevate your purchasing experience by requesting a tailored quote or use the Kalstein Plus platform for instant pricing, enhancing convenience and personalization.
Frequently Asked Questions
- What applications is the YR05493 recommended for?
The YR05493 excels in color control tasks across industries including plastics, textiles, ceramics, printing, and is notably effective with fluorescent samples. - Is the YR05493 compatible with PCs?
Yes, the spectrophotometer includes PC-compatible color management software for detailed data analysis and management. - What is the storage capacity?
The device can store up to 1,000 standards and 30,000 samples, making it ideal for thorough and organized record-keeping.
Advantages and Disadvantages
The YR05493 boasts high precision with a ΔE*ab standard deviation of just 0.03, adaptability to multiple measurement apertures, and compatibility with various color spaces and illuminants. With USB and Bluetooth 4.2 connectivity, data transfer is seamless. However, its 400-700 nm wavelength range may not be suitable for applications requiring a broader spectrum.
Field Applications
In environments where high color accuracy is critical, such as plastics, textiles, coatings, and ceramics manufacturing, the YR05493 proves its versatility. With SCI and SCE measurement modes and adaptable apertures, it consistently meets unique sample needs. Additionally, it is valuable for color verification in signage and reflective films, making it essential in laboratory and production line settings.
Recommendations
Regular calibration is essential for optimal performance of the YR05493. Storing it in a clean, dust-free environment will preserve its functionality. With a lithium-ion battery supporting up to 6,000 measurements over 8 hours, consistent recharging is suggested. For tailored insights on improving your industry’s color control efficiency, request a personalized quote or use Kalstein Plus for quick quote generation.
Features
- Three adaptable measurement apertures for various sample sizes
- Stable and precise 1000-line grating technology
- High storage capacity for extensive sample recording
- USB and Bluetooth 4.2 connectivity for data transfer
- Ergonomic design with dual optical structure for SCI/SCE measurements
- Conforms to international standards for accurate and reliable performance
Technical Specifications
Model | YR05493 |
Optical Geometry | D/8 (diffused illumination, 8-degree viewing angle) |
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source | |
Conforms to CIE No.15, GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 | |
Characteristic | 3 measuring apertures for accurate color analysis and transmission in laboratory |
It is used for precise color measurement and quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries, and for fluorescent sample measurement. | |
Integrating Sphere Size | Φ40mm |
Light Source | Combined full spectrum LED light source, UV light source |
Spectrophotometric Mode | Flat Grating |
Sensor | Silicon photodiode array (double row 40 groups) |
Wavelength Range | 400~700nm |
Wavelength Interval | 10nm |
Semiband Width | 10nm |
Measured Reflectance Range | 0-200% |
Measuring Aperture | 3 apertures: MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm;LAV:1x3mm |
LAV1x3mm: Slightly poor accuracy, can be used for color test | |
Specular Component | SCI&SCE |
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99 Munsell(C/2)) |
Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) |
Other Colorimetric Index | WI(ASTM E313,CIE/ISO,AATCC,Hunter), |
YI(ASTM D1925,ASTM 313), | |
Metamerism Index MI, | |
Staining Fastness, Color Fastness, Color Strength, Opacity, | |
8° Glossiness,555 tone classification | |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
Measuring Time | About 1.5s (Measure SCI & SCE about 3.2s) |
Repeatability | Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%) |
Chromaticity value: MAV/SCI, within ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
Inter-instrument Error | MAV/SCI, Within ΔE*ab 0.15 |
(Average for 12 BCRA Series II color tiles) | |
Measurement Mode | Single Measurement, Average Measurement(2-99times) |
Locating Method | Camera Locating,stabilizer cross position |
Dimension | L*W*H=129X76X217mm |
Weight | Approx 600g |
Battery | Li-ion battery, 6000 measurements within 8 hours |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Displayed Data | 3.5-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB, Bluetooth 4.2 |
Data Storage | Standard 1000 Pcs, Sample 30000 Pcs |
Language | Simplified Chinese, English, traditional Chinese |
Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
Storage Environment | -20~50℃, 0~85%RH (no condensing) |
Standard Accessory | Power Adapter, User Guide, PC Software(Download from office website), USB cable, White and Black Calibration Cavity, Protective Cover, Wrist strap, 8mm flat aperture, 8mm tip aperture, 4mm flat aperture, 4mm tip aperture,1x3mm tip aperture |
Optional Accessory | Micro Printer, Powder Test Box, Holding base |
Notes | The specifications are subject to change without notice. |