Pulsed Xenon lamp Benchtop Spectrophotometer YR05475

ManufacturerKalstein

Description

The Pulsed Xenon Lamp Benchtop Spectrophotometer YR05475 is a cutting-edge device engineered by Kalstein for precise color and appearance measurements in a wide range of laboratory and industrial settings. Equipped with a long-lasting pulsed xenon lamp, this spectrophotometer ensures exceptional stability for each analysis. It features a user-friendly 7-inch TFT touchscreen and supports advanced optical geometries, such as reflective d/8 and transmissive d/0, with options to include or exclude UV. The dual-array 256-element CMOS sensor and automatic aperture identification system offer unmatched accuracy for both solid and liquid samples. This makes it an ideal choice for professionals seeking consistent and detailed results.

Market Price

The YR05475 spectrophotometer offers an excellent balance of features and affordability, making it accessible to sectors like plastics, paint, food, cosmetics, and medicine where accurate color analysis is paramount. This competitively priced device can be tailored to meet industry-specific needs through the Kalstein Plus platform, which enables you to request a customized and obligation-free quote effortlessly.

Frequently Asked Questions

  • Can the YR05475 measure both transparent and opaque samples?
    Yes, this spectrophotometer is specifically designed to analyze both opaque and translucent materials, including clear liquids and solid samples.
  • How much data can the YR05475 store?
    It can store up to 20,000 results, which is highly useful for comprehensive and detailed test data monitoring.
  • Are the measurement apertures adjustable?
    Absolutely, the YR05475 offers three adjustable apertures (Φ25.4 mm, 8 mm, and 4 mm) for flexibility with various sample types.

Advantages and Disadvantages

One of the standout features of the YR05475 is its temperature compensation system, ensuring precise readings even under varying environmental conditions. It also includes comprehensive lighting options (LED and UV) and has an ergonomic design suited for heavy use. A potential downside is the requirement for periodic calibration in high-usage environments to maintain accuracy.

Field Use

Ideally suited for quality control and product development laboratories, this spectrophotometer excels in demanding sectors such as automotive, cosmetics, medical, and food. Its dual capability to measure reflectance and transmittance across diverse materials streamlines the quality verification process, promoting high standards at each production stage.

Recommendations

For the best performance and longevity of the YR05475, it is recommended to perform regular calibrations and keep the device in a stable, clean environment. Adjusting the measurement aperture to match the sample type and specific test conditions will further enhance accuracy. Visit the Kalstein Plus platform today to request a personalized quote and explore how the YR05475 Benchtop Spectrophotometer can elevate your quality control and color analysis precision.

Features

  • Pulsed xenon lamp for longevity and stability
  • 7-inch TFT touchscreen for intuitive operation
  • Dual-array 256-element CMOS sensor
  • Automatic aperture identification with adjustable settings
  • Storage capacity of 20,000 records

Technical Specifications

Model YR05475 (Pulsed xenon lamp)
Optical Geometry Reflectance: d/8 (SCI⪰ Include UV/Exclude UV)
Transmittance: d/0 (SCI⪰ Include UV/Exclude UV); Haze(ASTM D1003)
Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7
Integrating Sphere Size Φ 154mm
Light Source Device 360nm-780nm Xenon Lamp, 400nm cut-off Xenon Lamp
Spectrophotometric Mode Concave Grating
Sensor 256 Image Element Double Array CMOS Image Sensor
Wavelength Range 360-780nm
Wavelength Pitch 10nm
Semiband Width 5nm
Reflectance Range 0~200%
Measuring Aperture Reflective: Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive: Φ30mm/Φ25.4mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position
Specular Component Reflectance: SCI&SCE
Transmittance: SCI&SCE
Color Space CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy
Color Difference Formula ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99
Colorimetric Index WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003)
Observer Angle 2° & 10°
Illuminants D65, A, C, UV, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12
Displayed Data Spectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset
Measuring Time About 2.4s (Measure SCI & SCE about 5s)
Repeatability Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.06%)
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.07%)
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.018 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Inter-instrument Error Φ25.4mm/SCI, Within ΔE*ab 0.15
(Average for 12 BCRA Series II color tiles)
Size 370×300×200mm
Weight About 9.6kg
Power Supply DC 24V, 3A Power Adapter
Light Source Device Life 5 years, more than 3 million times measurements.
Display 7″ TFT Capacitive Screen-touch Display
Data Port USB & Print serial port
Data Storage Standard 2000 Pcs, Sample 20000 Pcs
Language Simplified Chinese, Traditional Chinese, English,
Working Environment Temperature: 0~40℃; Humidity: 0~85% (No Condensation)
Storage Environment Temperature: -20~50℃; Humidity: 0~85% (No Condensation)
Standard Accessory Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber,
Optional Accessory Micro-printer, Transmissive Test Clamp Component,Micro Aperture(4mm) transmission test clamp component, Instrument inversion components
Notes: The specifications are subject to change without notice.

Additional information

Weight 12,5 kg
Dimensions 51 × 45 × 33 cm

Quote List

Quote List

No products in the list

Product categories

FAQ

Do you need help?

If you have any questions before processing the order, take a look at the most frequently asked questions

Do you want to know the cost of air shipping to your establishment?

Place your address in the payment area and you will automatically see the shipping to your door!

I am an institution; I need to know the price for several units; I would like to know the cost of the maritime freight

Request a custom quote in the contact section once you identify the model.