Description
The Automatic Nucleic Acid Extractor YR01870 is a cutting-edge instrument designed to streamline the nucleic acid extraction process using advanced magnetic bead technology. Ideal for molecular diagnostics, genetic identity testing, forensic medicine, biomedical research, and gene expression analysis, this state-of-the-art device features a preloaded protocol system and unique sample preparation kits to ensure high-purity extractions. By minimizing manual errors, it optimizes laboratory efficiency and performance. Its flexible processing capabilities, ranging from 30 to 1000 mL, along with a recommended sample volume of 200 µL, make it highly efficient and reliable. The device also supports cloud-enabled control via Android smartphones or tablets, allowing for seamless remote management. Additionally, it comes equipped with integrated UV disinfection and cross-contamination prevention measures for precise results. The user-friendly interface makes it accessible even for beginners, offering a smooth user experience with just a few clicks.
Market Price
The market offers various pricing options for the Automatic Nucleic Acid Extractor YR01870, depending on the supplier and included services such as technical support and specialized consumables. To explore customized pricing and potential discounts, consider generating an automatic quote through the Kalstein Plus platform.
Frequently Asked Questions
- How is nucleic acid extraction performed with the YR01870? The process is executed using convenient magnetic bead-based kits preloaded with reagents that simplify it, reducing manual errors to a single step.
- How many samples can be processed at once? The YR01870 can handle up to 32 samples simultaneously in just 15 minutes, contingent on the type of reagent used.
- How can I control the device? You can control the device via its keypad or remotely through an app on Android smartphones and tablets.
Advantages and Disadvantages
Advantages:
- High Efficiency: Capable of extracting multiple samples quickly and simultaneously.
- Ease of Use: Features an intuitive software interface and mobile remote control for user-friendliness.
- Contamination Control: Equipped with UV disinfection and measures against cross-contamination for reliable results.
- Versatility: Suitable for diverse applications, including medical diagnostics and scientific research.
Disadvantages:
- High Price: While providing exceptional performance, the cost might be challenging for small labs with limited budgets.
- Requires Specialized Maintenance: Optimal performance requires maintenance by trained personnel.
Product Use in the Field
The Automatic Nucleic Acid Extractor YR01870 finds application in genetic research labs, hospitals, diagnostic centers, and forensic labs. Its capacity to process large sample volumes swiftly makes it invaluable in time-sensitive scenarios. Moreover, its compact and functional design is ideal for labs with limited space or those requiring portable equipment for field research or mobile testing applications.
Recommendations
Enhance the performance of the Automatic Nucleic Acid Extractor YR01870 by adhering to the manufacturer’s maintenance guidelines, which include regular cleaning, reagent monitoring, and software updates. Consider utilizing multiple protocols simultaneously to boost lab productivity. Remember to leverage the UV disinfection and cross-contamination prevention features for error-free outcomes and accurate analyses.
Characteristics
- Advanced magnetic bead-based nucleic acid extraction
- Cloud-enabled remote device management
- UV disinfection system for contamination control
- Intuitive software for user-friendly operation
- Compact design for flexible deployment
Technical Specifications
Model | YR01870 |
Throughput | 32 |
Processing Volume | 30-1000mL |
Recommended Sample Volume | 200uL |
Magnetic Bead Residue | £1% |
Suitable Consumables | 96-well plates, 6- tube strips |
Heating Temperature | Lysis heating: room temperature to 120°C |
Elution heating: room temperature to 120°C | |
Mixing Mode | Optional multi-modes and multi-gears for mixing |
Reagent Type | Magnetic beads-based extraction kits |
Operation Mode | A. Cloud-enabled control via smart phones/tablets (Android) |
B. Machine keypad operation | |
Experimental Storage | Up to >500 groups of programs saved in the Android app |
Up to 15 groups of programs saved in device | |
Program Management | Programs can be created, edited, applied and deleted with high flexibility |
Contamination Control | Built-in UV disinfection module |
Power Failure Protection | Choose freely whether or not to continue the experiment when the power is on again after cutting off |
Connection port type | USB, Ethernet, USB Type-B |
Network Connection | Cloud-enabled control on smart phone/tablet |
Instrument Dimensions | 435mmx440mmx445mm (WxLxH) |
Weight | 31.5kg (net) |
Power Supply | AC 100-240V. 50/60+1Hz: 600w |
Operating temperature range | 10~30°C |
Operating humidity range | 20%-85% |